Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMJ Paediatr Open ; 7(1)2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37844971

RESUMO

OBJECTIVE: Investigating the clinical implications of isolated white matter abnormalities on neonatal brain MRI in congenital cytomegalovirus (CMV). DESIGN: Prospective, observational. PATIENTS/INTERVENTIONS: Two paediatric radiologists, blinded to clinical data, independently scored the white matter in 286 newborns with congenital CMV. After assessing interobserver variability, mean score was used to categorise white matter (normal, doubtful or abnormal). Patients with other brain abnormalities were excluded. MAIN OUTCOME MEASURES: Hearing and neuromotor evaluation. RESULTS: Cohen's weighted kappa was 0.79 (95% CI 0.73 to 0.84). White matter was normal in 121 patients, doubtful in 62, abnormal in 28. Median clinical follow-up was 12.0 months (IQR 12.0-27.7 months). Neonatal hearing loss occurred in 4/27 patients (14.8%) with abnormal, 1/118 patients (0.8%) with normal and 1/62 patients (1.6%) with doubtful white matter (p<0.01). Impaired cognitive development was seen in 3/27 patients (11.1%) with abnormal, 3/114 patients (2.6%) with normal and 1/59 patients (1.7%) with doubtful white matter (p=0.104). Alberta Infant Motor Scale (AIMS) was below P75 in 21/26 patients (80.8%) with abnormal, 73/114 patients (64.0%) with normal and 36/57 patients (63.2%) with doubtful white matter (p=0.231). In a subgroup of patients with minimal clinical follow-up of 18 months, AIMS score was below P75 in 10/13 patients (76.9%) with abnormal, 13/34 patients (38.2%) with normal and 7/20 patients (35.0%) with doubtful white matter (p<0.05). CONCLUSIONS: Abnormal white matter was associated with neonatal hearing loss and mild, lower motor scores. A tendency towards impaired cognitive development was seen. Patients with doubtful white matter did not show worse clinical outcome.


Assuntos
Infecções por Citomegalovirus , Perda Auditiva , Substância Branca , Criança , Humanos , Lactente , Recém-Nascido , Infecções por Citomegalovirus/complicações , Infecções por Citomegalovirus/diagnóstico por imagem , Infecções por Citomegalovirus/congênito , Perda Auditiva/complicações , Imageamento por Ressonância Magnética , Estudos Prospectivos , Substância Branca/diagnóstico por imagem
2.
Brain Sci ; 13(10)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37891851

RESUMO

This study aims to explore the effect of cochlear implantation on tinnitus perception. A prospective study was conducted on 72 adult hearing-impaired patients to evaluate tinnitus perception before and after cochlear implantation, using standardized tinnitus questionnaires (the tinnitus sample case-history questionnaire, tinnitus functional index (TFI), and tinnitus handicap inventory (THI)). A large variety of demographic and hearing- and implant-related data was collected from patient hospital records to explore possible associations with the implantation effect. The prevalence of tinnitus complaints before implantation was 58.3%. The temporary induction or aggravation of tinnitus immediately after surgery was noted in 20% and 46.7% of patients, respectively. When evaluated 3 months after implantation, 60% of tinnitus patients experienced a clinically significant reduction in their complaints; most of the improvements were experienced immediately after activation of the implant. Only the scores for TFI and THI at baseline were found to be significantly correlated with a reduction in TFI scores after implantation. In 80% of tinnitus patients, the tinnitus remained suppressed for some time after taking off the device. The large subset of patients with residual inhibition supports the involvement of central pathophysiological processes in implantation effects on tinnitus, which are explored in this paper.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...